CAR - Artigos publicados em revistas indexadas
Permanent URI for this collection
Browse
Browsing CAR - Artigos publicados em revistas indexadas by Author "Adjedj, J"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
- Continuum of Vasodilator Stress From Rest to Contrast Medium to Adenosine Hyperemia for Fractional Flow Reserve Assessment.Publication . Johnson, N; Jeremias, A; Zimmermann, F; Adjedj, J; Witt, N; Hennigan, B; Koo, B; Maehara, A; Matsumura, M; Barbato, E; Esposito, G; Trimarco, B; Rioufol, G; Park, S; Yang, H; Baptista, SB; Chrysant, G; Leone, A; Berry, C; De Bruyne, B; Gould, K; Kirkeeide, R; Oldroyd, K; Pijls, N; Fearon, WOBJECTIVES: This study compared the diagnostic performance with adenosine-derived fractional flow reserve (FFR) ≤0.8 of contrast-based FFR (cFFR), resting distal pressure (Pd)/aortic pressure (Pa), and the instantaneous wave-free ratio (iFR). BACKGROUND: FFR objectively identifies lesions that benefit from medical therapy versus revascularization. However, FFR requires maximal vasodilation, usually achieved with adenosine. Radiographic contrast injection causes submaximal coronary hyperemia. Therefore, intracoronary contrast could provide an easy and inexpensive tool for predicting FFR. METHODS: We recruited patients undergoing routine FFR assessment and made paired, repeated measurements of all physiology metrics (Pd/Pa, iFR, cFFR, and FFR). Contrast medium and dose were per local practice, as was the dose of intracoronary adenosine. Operators were encouraged to perform both intracoronary and intravenous adenosine assessments and a final drift check to assess wire calibration. A central core lab analyzed blinded pressure tracings in a standardized fashion. RESULTS: A total of 763 subjects were enrolled from 12 international centers. Contrast volume was 8 ± 2 ml per measurement, and 8 different contrast media were used. Repeated measurements of each metric showed a bias <0.005, but a lower SD (less variability) for cFFR than resting indexes. Although Pd/Pa and iFR demonstrated equivalent performance against FFR ≤0.8 (78.5% vs. 79.9% accuracy; p = 0.78; area under the receiver-operating characteristic curve: 0.875 vs. 0.881; p = 0.35), cFFR improved both metrics (85.8% accuracy and 0.930 area; p < 0.001 for each) with an optimal binary threshold of 0.83. A hybrid decision-making strategy using cFFR required adenosine less often than when based on either Pd/Pa or iFR. CONCLUSIONS: cFFR provides diagnostic performance superior to that of Pd/Pa or iFR for predicting FFR. For clinical scenarios or health care systems in which adenosine is contraindicated or prohibitively expensive, cFFR offers a universal technique to simplify invasive coronary physiological assessments. Yet FFR remains the reference standard for diagnostic certainty as even cFFR reached only ∼85% agreement.
- Predictive factors of discordance between the instantaneous wave-free ratio and fractional flow reserve.Publication . Dérimay, F; Johnson, N; Zimmermann, F; Adjedj, J; Witt, N; Hennigan, B; Koo, B; Barbato, E; Esposito, G; Trimarco, B; Rioufol, G; Baptista, SB; Chrysant, G, et al.OBJECTIVES: To identify clinical, angiographic and hemodynamic predictors of discordance between instantaneous wave-free ratio (iFR) and fractional flow reserve (FFR). BACKGROUND: The iFR was found to be non-inferior to the gold-standard FFR for guiding coronary revascularization, although it is discordant with FFR in 20% of cases. A better understanding of the causes of discordance may enhance application of these indices. METHODS: Both FFR and iFR were measured in the prospective multicenter CONTRAST study. Clinical, angiographic and hemodynamic variables were compared between patients with concordant values of FFR and iFR (cutoff ≤0.80 and ≤0.89, respectively). RESULTS: Out of the 587 patients included, in 466 patients (79.4%) FFR and iFR agreed: both negative, n = 244 (41.6%), or positive, n = 222 (37.8%). Compared with FFR, iFR was negative discordant (FFR+/iFR-) in 69 (11.8%) patients and positive discordant (FFR-/iFR+) in 52 (8.9%) patients. On multivariate regression, stenosis location (left main or proximal left anterior descending) (OR: 3.30[1.68;6.47]), more severe stenosis (OR: 1.77[1.35;2.30]), younger age (OR: 0.93[0.90;0.97]), and slower heart rate (OR: 0.59[0.42;0.75]) were predictors of a negative discordant iFR. Absence of a beta-blocker (OR: 0.41[0.22;0.78]), older age (OR: 1.04[1.00;1.07]), and less severe stenosis (OR: 0.69[0.53;0.89]) were predictors of a positive discordant iFR. CONCLUSIONS: During iFR acquisition, stenosis location, stenosis degree, heart rate, age and use of beta blockers influence concordance with FFR and should be taken into account when interpreting iFR.