Repository logo
 
Publication

Are we all doing it wrong? Influence of stripping and cleaving methods of laser fibers on laser lithotripsy performance.

dc.contributor.authorKronenberg, P
dc.contributor.authorTraxer, O
dc.date.accessioned2019-06-19T14:51:53Z
dc.date.available2019-06-19T14:51:53Z
dc.date.issued2015
dc.description.abstractPURPOSE: We assessed whether stripping and cleaving the laser fiber tip with specialized tools, namely laser fiber strippers, or ceramic or metal scissors, would influence lithotripsy performance. MATERIALS AND METHODS: Laser fiber tips were stripped with a specialized laser fiber stripper or remained coated. The tips were then cleaved with metal or ceramic scissors. Laser lithotripsy experiments were performed with the 4 fiber tip combinations using an automated laser fragmentation testing system with artificial stones made of plaster of Paris or BegoStone Plus (Bego, Lincoln, Rhode Island). High frequency-low pulse energy (20 Hz and 0.5 J) and low frequency-high pulse energy (5 Hz and 2.0 J) settings were used for 30 seconds. Fissure width, depth and volume, and laser fiber tip photos were analyzed. RESULTS: Coated laser fiber tips always achieved significantly higher ablation volumes (sometimes greater than 50%) than stripped laser fiber tips (p <0.00001) regardless of cleaving scissor type, stone material or lithotripter setting. Coated fiber tips cleaved with metal scissors ablated as well as those cleaved with ceramic scissors (p = 0.16). However, stripped fibers were much less ablative when they were cut with metal scissors compared to ceramic scissors (p <0.00001). Harder stone material decreased ablation volume (p <0.00001). Low frequency-high pulse energy settings were an average of 3 times more ablative than high frequency-low pulse energy settings (p <0.00001). Stripping the fibers, a harder stone material and low frequency-high pulse energy settings were associated with increased fiber tip degradation. CONCLUSIONS: Coated laser fibers provided better lithotripsy performance and metal scissors were as good as ceramic scissors to cleave coated fibers. This knowledge may improve and simplify the way that laser lithotripsy procedures are done worldwide.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationJ Urol. 2015 Mar;193(3):1030-5.pt_PT
dc.identifier.doi10.1016/j.juro.2014.07.110.pt_PT
dc.identifier.issn1527-3792
dc.identifier.urihttp://hdl.handle.net/10400.10/2295
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.publisherLippincott Williams & Wilkinspt_PT
dc.subjectLaser lithotripsypt_PT
dc.titleAre we all doing it wrong? Influence of stripping and cleaving methods of laser fibers on laser lithotripsy performance.pt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.conferencePlaceBaltimorept_PT
oaire.citation.titleJournal of Urology, Thept_PT
rcaap.rightsclosedAccesspt_PT
rcaap.typearticlept_PT

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
J Urol. 2015 a.pdf
Size:
1.26 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: